11KW OBC Liquid System  |Products|Chargers(OBC)

11KW OBC Liquid System


Model No.:ATC11K-380S380-W

Power:11KW

Input Voltage:304~456VAC 175~265VAC

Output Voltage:200~450 400~650 450~750VDC

Output Current:32 23 20A

Efficiency:94%

Code 11KW_OBC_Liquid






Download:Model No_ATC11K-380S380-W
 Specification

Download:Model No_ATC11K-380S540-W
 Specification

Download:Model No_ATC11K-380S640-W
 Specification


Download:Model No_ATC11K-380S380-W, ATC11K-380S540-W, ATC11K-380S640-W 3D Drawing


Features 
● Output Power:11KW(Rated 220V)/5KW (Rated 110V)
● Input Voltage:
3 phase 304~456 VAC
1 phase 175~265 VAC
● Output Voltage:200~450 400~650 450~750VDC
● Dimensions:369x238x98mm
● Cooling System:Liquid
● Communication:CAN
● Standard:SAE
● Enclosure: Aluminum alloy made
● Software: Digital software design
● Weight :≦10KG


Series Specification

Item Part Name Model Name Power (W) Input Voltage (VAC) Output Voltage (VDC) Output Current (A) Efficiency Size (mm) Cooling System Weight (Kg) Certificate
1 11KW OBC ATC11K-380S380-W 11000 3 phase 304~456
1 phase 175~265
200~450 32 94% 369x238x98 Liquid 10.5 GB/T
2 ATC11K-380S540-W 400~650 23
3 ATC11K-380S640-W 450~750 20 CE , GB/T


Specification

Specification Remark
Environmental characteristics Operating temperature -40~85℃ long-time working
Vibration/noise Meet the QC/T 895-2011 standard  
Salt spray experiment Meet the QB/T 2423.17-2008 standard  
Output Power Three phase 11KW / single phase 6.6KW  
Input voltage range Three-phase 304~456VAC (line-to-line voltage, three-phase four-wire)
Single phase 176~265VAC
 
Output voltage range 200~450VDC  
Low voltage input auxiliary source 13.8VDC(4Amax)  
Activation method CP/CC/hard wire  
Voltage accuracy ±1%  
Output maximum current 11KW Three phase: 32A,
6.6KW single phase: 20A
 
Voltage ripple factor ≤±1%  
Current accuracy ±3% ≧Half load
Effectiveness ≥94%

Rated voltage

Full load
Output response time The rise time of the output voltage of the car charger should be less than 300ms, and the overshoot should be less than 10%. After receiving the shutdown command, the current drops below 10% within 300ms and drops to 0A within 500ms.  
Other protection features Input overvoltage,
input undervoltage,
output overvoltage,
output undervoltage,
short circuit,

 
 

 

 


Add to inquiry

Faded Short Sleeve T-shirts

11KW OBC Liquid System

Model No.:ATC11K-380S380-W

Power:11KW

Input Voltage:304~456VAC 175~265VAC

Output Voltage:200~450 400~650 450~750VDC

Output Current:32 23 20A

Efficiency:94%