8KW Battery Thermal Management System  |Products|BTMS

8KW Battery Thermal Management System


Model Name. : AT-QL-ETMS-LR-8

Power : 8KW

Compressor rated voltage: 540VDC

Compressor operating voltage : 400-750VDC

Low voltage rated voltage: 24VDC

Dimensions: 845x543x290mm

Weight : 46KG

Code AT-QL-ETMS-LR-8





Download:  8KW Battery Thermal Management System Specification.pdf


Specification
 

Item

Description

Technical specifications

1

Product name

8KW Battery Thermal Management System

2

Model No.

AT-QL-ETMS-LR-8

3

Weight

46kg

4

Dimensions

845x543x290mm

5

Rated cooling capacity

1-8KW

6

Condensing air volume (m3/h)

3600

7

Water pump

DC24VDC190W

8

Circulating water volume (L/min)

30(lift>10 meters)

9

Nozzle diameter

φ 25

10

Coolant outlet temperature

10-35℃

11

Compressor rated voltage

540VDC

12

Compressor operating voltage

400-750VDC

13

Refrigerant type

R134a

14

Waterproof for whole unit

IP54

15

Low voltage electrical for unit

IP66

16

Protection of high-voltage components

IP67

17

Coolant

50% ethylene glycol

18

Communication method

CAN2.0

Environment

1

Ambient temperature

-30~50℃

2

Coolant

Antifreeze (50% ethylene glycol aqueous solution)

3

Power supply type

DC

Electrical parameters

1

HV rated voltage

540VDC

2

High voltage range

400-750VDC

3

Low voltage rated voltage

24VDC

4

Low voltage range

19-32VDC

5

Compressor rated power

2.0KW

6

Air cooling fan rated power

250W*2

7

Fan maximum air volume (m3/h)

2000(single)


Add to cart