Description |
Technical specifications |
Remark |
Operating temperature |
-40~85℃ |
85~100℃,Can be derated to 40% of work |
Rated output power |
2.5KW |
|
Input voltage range |
250-450VDC/400-750VDC |
Optional |
Output rated voltage |
13.8VDC |
Adjustable |
Rated output current |
181A |
|
Auxiliary power VCC |
9-18VDC |
|
Efficiency |
≥95% |
ted voltage Full load |
Output voltage ripple |
≤500mVPK-PK |
|
Protection characteristics |
Input over-voltage, output over-voltage, input anti-reverse connection, output over-current and short-circuit protection, over-temperature self-recovery |
|
Over temperature protection |
The bottom plate temperature reaches 85 °C and starts derating output. The temperature exceeds 100 °C, shutting down; the temperature is lower than 95 °C, which can be self-recovery. |
|
Dielectric strength |
Input to output |
2500VDC/1min 1mA max |
|
Input to the outer casing |
2500VDC/1min 1mA max |
|
Insulation resistance |
Input to output |
≥20MΩ |
|
nput to the outer casing |
≥20MΩ |
|
Battery compatibility |
Radiation emission |
GB/T 18655-2010 Class 3 |
|
Conducted emission |
GB/T 18655-2010 Class 3 |
|
Static immunity |
GB/T 19951-2005 |
Air discharge:15KV,Contact discharge 8KV |
Radiation immunity |
GB/T 18655-2010 Class 3 |
|
High current injection |
GB/T 17619-1998 |
|
Fast burst immunity |
GB/T 17626.4-2008 1KV |
|