Output Power:1000W
Input Voltage:65~100Vdc
Output Voltage:13.6±0.6VDC
Cooling System:Natural Air or Forced Air
Specifications |
Value |
Range |
Unit |
Remark |
||
Electricl |
Input |
Rated Input Voltage |
80 |
65~100 |
VDC |
|
Rated Input Current |
12 |
|
A |
|
||
Output |
Rated Output Voltage |
13.6 |
±0.6% |
VDC |
|
|
Rated Output Current |
74 |
|
A |
|
||
Rated Output DC Power |
1000 |
|
W |
|
||
Efficiency |
>90 |
|
% |
|
||
Ripple & Noise |
680 |
|
mVp-p |
|
||
Protection |
Input |
Input Over-voltage Protection(OVP) |
105 |
±5% |
VDC |
|
Input Under-voltage Protection(UVP |
60 |
±5% |
VDC |
|
||
Output Over Current Protection(OCP) |
17 |
±2% |
A |
|
||
Output |
Output Over Current Protection(OCP) |
80 |
±2% |
A |
|
|
Short circuit protection |
100 |
|
A |
|
||
Other |
Over temperature protection(OTP) |
85 |
|
°C |
|
|
Feature |
|
System indicator |
N/A |
|
|
(Standby) |
|
N/A |
|
|
(Error) |
||
|
Input reverse protection |
Y |
|
|
|
|
Safety and EMC |
|
Isolation voltage |
I/P-O/P:1.5kVac I/P-FG :2kVac O/P-FG:0.5kVac |
|
|
|
|
Insulation resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC /25°C/70% RH |
|
|
|
|
|
EMI/EMC |
EN15194; GBT24347 |
|
|
|
|
Environmental |
|
Operating temperature |
-20°C~85°C |
|
|
|
|
Working humidity |
5% to 95% RH |
|
|
|
|
|
Cooling method |
Natural Air or Forced Air (To be verified) |
|
|
|
|
Mechanical |
|
IP rating |
IP54 |
|
|
|
|
Application |
Electric Rail Car Mover |
|
|
|