Model No.: AR2K5D6K6B-220S350L-I
Electrical characteristics
1. OBC Charging mode:
Item |
specification |
AC input |
|
Input voltage range |
85~265 Vac |
Rated input voltage |
220 Vac |
Input frequency range |
45-65 Hz |
Input Current |
32 A max |
Power Factor |
0.99@ Rated |
High voltage output |
|
Output voltage range |
240~450Vdc |
Rated output voltage |
350 Vdc |
Output current |
22 A |
Output voltage accuracy |
≤±1% |
Output current accuracy |
≤±3%@>10A;≤±0.3A @<10A |
Output voltage ripple coefficient |
≤±5%(CV mode) |
Output Power |
6.6 kW max |
Efficiency |
94% |
Low-voltage input |
|
Input voltage range |
9~16 Vdc(normal work) |
Quiescent Current |
≤1 mA(Total 2 in 1) |
communication method |
CAN2.0,500kbs |
Wake up |
CC wake up, CP wake up |
With or without termination resistor |
no |
Protective function |
|
Input over and under voltage protection, output over and under voltage protection, over temperature protection, short circuit protection, reverse output protection |
2. DC/DC mode:
Item |
specification |
High voltage input |
|
Input voltage range |
240~450 Vdc |
Rated input voltage |
350 Vdc |
Input current |
12 A |
Low voltage output |
|
Output rated voltage |
14±0.25 Vdc |
Output current |
180 A continuous |
Output Power |
2.5 KW continuous |
Efficiency |
92% |
Output voltage accuracy |
≤±2% |
Output voltage ripple coefficient |
≤800 mV@20 MHz |
Output voltage overshoot |
≤5% Vout |
Low-voltage input |
|
Input voltage range |
9 ~ 16 Vdc (normal operation) |
Quiescent Current |
≤1 mA (2 in 1 total) |
communication method |
CAN2.0,500kbs |
Wake up |
Hard-wired wake |
With or without termination resistor |
no |
Protective function |
|
Input over and under voltage protection, output over and under voltage protection, over temperature protection, short circuit protection |