Model No.:AR-TDC-IY-72/108/144/320-12
Power:1KW
Input Voltage:44-97/72-162/170-300/220-450V
Output Voltage:14.0V
Output Current:72A
Efficiency:94%
Via CAN BUS, functions, OBD diagnosis, working status display, modifying working parameters, encoding, etc, are achievable.
Protection function including reverse protection, input lower voltage and over voltage protection, output over voltage , output over current, output short circuit protection, over heating protection etc,.
Input terminal pre-charge function.
Fully sealed waterproof structure, natural air cooling
Nominal Input |
Nominal Output |
Model |
Configuration |
Heating Dissipation Mode |
72V |
14.0V |
TDC-IY-72-12 |
CANxxxx/N |
Natural Air Cooling |
96V/108 |
14.0V |
TDC-IY-108-12 |
CANxxxx/N |
Natural Air Cooling |
144V |
14.0V |
TDC-IY-144-12 |
CANxxxx/N |
Natural Air Cooling |
320V |
14.0V |
TDC-IY-320-12 |
CANxxxx/N |
Natural Air Cooling |
Model | TDC-IY-72-12 | TDC-IY-108-12 | TDC-IY-144-12 | TDC-IY-320-12 | |
Input | Nominal Voltage | DC72V | DC96V/DC108V | DC144V | DC320V |
Nominal Current | 15A | 10A/11A | 5A | 3.5A | |
Max Working Current | ≤25A | ≤18A | ≤12A | ≤8A | |
The range of The range of | 44-97V | 72-162V | 100-200V | 220-450V | |
The protection of under voltage | 42V±2V | 70V±2V | 96V±4V | 215V±5V | |
The protection of over voltage |
100±3V | 162±4V | 215±5V | 455±5V | |
Activation Time | ≈0.5S @ VIN=72V | ≈0.5S @ VIN=108V | ≈0.5S @ VIN=144V | ≈0.5S @ VIN=320V | |
Output | Nominal Voltage | 14.0V±1% | |||
Voltage Range | 8.0-15V | ||||
Nominal Output Current | 72A | ||||
Nominal Output DC Power | 1000W | ||||
Peak Power | 1200W Continues 6 Minutes | ||||
Max Efficiency | ≥94% | ||||
Instant Responding | ≤50ms | ||||
The Adjustmen rate of voltage | 1% | ||||
The Adjustment rate of loading | ≤1% | ||||
The steady voltage accuracy | ≤1% | ||||
The steady current accuracy | ≤2% | ||||
The leaking current of output terminal | ≤1mA | ||||
The current leakage | ≤1mA | ||||
The Output Ripple | ≤276mV @ 12V | ||||
Signal | 12Enable Signal | 6-30V | |||
12V Enable current | ≤1mA | ||||
Safety Regulation and Other | Hi pot Test | Input to earth: 2000VAC<10ma 1 min. | |||
Grounding Resistance | The value of the resistor between grounding and heating sink is smaller than 100 ohm.. The testing current is 25A AC. | ||||
Voltage Resistance | 2000V Between Input terminal and shell, there is no Corona,ionization,Flying Fox,Breakdown phenomenon. | ||||
Insulation Resistance | In ambient temperature (23±2) ℃ and humidity 80%~90%, input to shell is not smaller than 20MΩ, testing voltage is 1000VDC. | ||||
Noisy | ≤50dB @ 1m away from converter | ||||
Electromagnetic Immunity | Compliant with GB/T 18487.3-2001 11.3.1 | ||||
Electromagnetic Abusive | Compliant with GB/T 18487.3-2001 11.3.2 | ||||
Harmonic Current | Compliant with GB 17625.1-2003 6.7.1. | ||||
Activation Inrush Current | ≤3A | ||||
Current Raise Time | 100% to 10% ≤50mS; 100% to 0% ≤200mS | ||||
Protection Grade | IP67 | ||||
Anti-Vibration | 10-25Hz, Amplitude 1.2mm, 25-500Hz 30m/s2, 8 h each direction | ||||
Reliability | MTBF 150000 H | ||||
Ambient Humidity | 5%~95% NO condensation | ||||
Ambient Temp. | -40 ~ 65℃ | ||||
Storage Temp. | -55℃ ~ +85℃ |
Items |
Testing Voltage |
Testing time |
Current Leakage value |
Input +&- to shell |
2800V DC |
1min |
≤0.1mA |
Output +&- to shell |
2000V AC |
1min |
≤10mA |
Items |
Testing Voltage |
Testing time |
Testing value |
Input +&- to shell |
1000V DC |
1min |
≥20M |
The Protection of under input voltage |
Shut off in 60s once Input voltage lower than protection value . Resume automatically in 120s after the fault is removed. |
The Protection of over input voltage |
Shut off once over input voltage is overt than the protection value;Resume automatically as long as default is removed. |
The reversion protection of input connection |
No damage, no working. Resume to work with normal wiring. |
The short circuit protection of Output |
When the output voltage is lower than 6V, output current descend to 1/4 of nominal current. .Resume automatically when the short circuit is removed , output voltage increased to above 6V. |
Over temperature protection |
Output power start to derating once shell temperature is over 85 deg. Shut off at 90 deg. |
HVIL |
Shut off if the input plug is unfasten or loose. |
Communication Protection |
The CAN communication invalid time is over 5s, converter shut off. |
Interface |
Terminal Definition |
Connecto r Socket |
Connector Plug |
Brand |
Input Connector |
|
2103124-4 |
2103177-4 |
Tyco |
Signal |
1-Enable
2-Failure Signal 3-HVIL 4-HVIL |
PP042730 3 |
/ |
THB |
DC Output + |
M8 Threaded hole |
/ |
/ |
/ |
DC Output - |
outer hexagonal flange M8 pole |
/ |
/ |
/ |